Annual electricity spend
Total U.S. facility electricity cost you want to model, in USD per year.
- Default
- $360,000
- Allowed range
- $10,000–$20,000,000
USD/year
GRIDFLEX · CALCULATOR NOTES
A transparent walkthrough of the inputs, arithmetic, and scenario ranges behind GridFlex’s commercial facility calculator.
01 / Inputs
Each default, allowed range, unit, and description comes from the live calculator configuration.
Total U.S. facility electricity cost you want to model, in USD per year.
USD/year
Your estimate of the annual spend linked to load the selected asset can influence.
Percent of annual electricity spend (%)
The facility’s highest monthly demand, measured in kW.
kW
The tariff demand charge used for this scenario, in USD per kW-month.
USD/kW-month
The reduction you want to test across the flexible-cost and demand-charge components.
%
Each slot can be labeled Battery storage, EV fleet, or Building systems. The selected context describes what you are considering; it does not change the formula or assumptions.
02 / Formulas
Percentage inputs become fractions by dividing by 100. The demand charge is monthly, so the formula annualizes it over 12 months.
Illustrative annual value
Energy-cost component = annual electricity spend × (controllable share ÷ 100) × (peak reduction ÷ 100)
Peak-demand component = monthly peak demand × demand charge × 12 × (peak reduction ÷ 100)
Illustrative annual value = energy-cost component + peak-demand componentIllustrative scenario peak reduction
monthly peak demand × (peak reduction ÷ 100)Dividing each percentage by 100 converts it to a fraction.03 / Scenario range
Low and High each adjust controllable share and peak reduction, then use the same formulas above. Annual spend, monthly peak demand, and demand charge stay fixed.
Subtract 5 percentage points from controllable energy-cost share and 3 percentage points from peak reduction.
Add 5 percentage points to controllable energy-cost share and 3 percentage points to peak reduction.
Each adjusted value is clamped to that input’s configured range. Controllable energy-cost share stays between 0% and 100%; peak reduction stays between 0% and 50%.
04 / Worked example
Every amount and kW output below is an illustrative scenario result calculated from the live model’s current defaults: $360,000 annual spend, 25% controllable share, 1,000 kW monthly peak, an $18/kW-month demand charge, and 10% peak reduction. These are not measured site outcomes.
Configured
25% share · 10% peak reductionLow case
20% share · 7% peak reductionHigh case
30% share · 13% peak reduction05 / Limits
Every amount and kW output on this page is an illustrative scenario only. They are not realized savings, a forecast, guaranteed savings, committed revenue, or a peak-reduction promise; the annual value is not net ROI. The model does not subtract asset or operating costs. Outcomes depend on site conditions, tariff structure, asset performance, operating schedules, program eligibility and terms, and market conditions.